Uploaded image for project: 'OpenNMS'
  1. OpenNMS
  2. NMS-12473

Cannot process SNMPv3 Informs due to random Engine ID associated with users

    XMLWordPrintable

    Details

    • Sprint:
      Horizon 2020 - January 22nd, Horizon 2020 - Feb 5th, Horizon 2020 - Feb 19th

      Description

      A customer has reported a problem on Trapd when receiving SNMPv3 Informs. Upon restarting OpenNMS, Trap stops processing Informs, and the following error appears on the log:

      2020-01-10 07:49:26,171 DEBUG [DefaultUDPTransportMapping_0.0.0.0/162] o.s.m.MPv3: RFC 3412 ยง7.2.13.a - Security engine ID ***** does not match local engine ID ***** 

      On the source code, a random Engine ID is associated with each USM User defined in trapd-configuration.xml, which is the behavior when an explicit ID is not passed when creating the UsmUser object, and I believe this is the source of the problem.

        Attachments

          Activity

            People

            Assignee:
            cgorantla Chandra Gorantla
            Reporter:
            agalue Alejandro Galue
            Votes:
            0 Vote for this issue
            Watchers:
            4 Start watching this issue

              Dates

              Created:
              Updated: