Uploaded image for project: 'OpenNMS'
  1. OpenNMS
  2. NMS-3574

Cisco temperature threshold too low

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 1.6.8
    • Fix Version/s: 1.10.0
    • Component/s: Thresholding
    • Security Level: Default (Default Security Scheme)
    • Labels:
      None
    • Environment:
      Operating System: Linux
      Platform: PC
    • Bugzilla Id:
      3529

      Description

      Hello,

      This is opennms threshold default configuration for cisco:

      <threshold type="high"
      ds-type="ciscoEnvMonTemperatureStatusIndex" value="40.0"
      rearm="37.0" trigger="3" ds-label="cvmTempStatusDescr" ds-name="cvmTempStatusValue"/>

      40C is too low and OpenNMS keeps warning it. I'll change on my config but opennms should have default configs meeting Cisco limits. Yellow limit is 55 and red limit is 65. This is my output in Cisco C3750

      #show env all
      FAN is OK
      TEMPERATURE is OK
      Temperature Value: 39 Degree Celsius
      Temperature State: GREEN
      Yellow Threshold : 55 Degree Celsius
      Red Threshold : 65 Degree Celsius

      Thanks!