Uploaded image for project: 'OpenNMS'
  1. OpenNMS
  2. NMS-4028

Thresholding - Absolutechange stored as floating-point value

    XMLWordPrintable

Details

    • Bug
    • Status: Closed (View Workflow)
    • Major
    • Resolution: Cannot Reproduce
    • 1.8.1
    • 1.9.92
    • Thresholding
    • Security Level: Default (Default Security Scheme)
    • None
    • Operating System: All
      Platform: PC
    • 3992

    Description

      When I create a AbsoluteChange threshold in the tresholding gui and enter for example 5 as a value then the value that goes into the configuration file is "5.0"

      When this is configured like this it seems like i get a notification on every value change.
      For example this threshold was triggered.
      parms: label="Unknown" ds="upsOutputCurrent1" value="65" instance="null" changeThreshold="5.0" previousValue="67"

      absoluteChange works though when I change the value manually in the thresholding.xml to be "5" instead of "5.0"

      Attachments

        Activity

          People

            agalue Alejandro Galue
            jt@jt.is Jon Thor Gudmundsson (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: