Uploaded image for project: 'OpenNMS'
  1. OpenNMS
  2. NMS-5357

Scheduled outages applied on latency thresholds are ignored by Pollerd.

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: 1.10.2
    • Fix Version/s: 1.10.3
    • Component/s: Thresholding
    • Security Level: Default (Default Security Scheme)
    • Labels:
      None

      Description

      Tim Miller Dyck from the mailing list has reported this problem.

      He was testing out ICMP latency thresholds. They were working fine (he can see alerts triggering at the expected latency values).

      However, He was not able to get threshold alerts to stop during scheduled outages where the ICMP latency threshold is marked to be ignored. The alerts continue throughout the outage.

      Other types of thresholds are stopping during scheduled outages as expected – just the ICMP latency outages aren't working for him.

      Checking the source code I've found that LatencyStoringServiceMonitorAdaptor is not checking if the node is on outage before applying the thresholds, and that's the reason of the problem.

        Attachments

          Activity

            People

            • Assignee:
              agalue Alejandro Galue
              Reporter:
              agalue Alejandro Galue
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: