Uploaded image for project: 'OpenNMS'
  1. OpenNMS
  2. NMS-8620

Restarting OMNS results in numerous SNMP outage alarms and notifications

    Details

    • Sprint:
      Horizon - Jan 18th

      Description

      Doing a ONMS restart results in numerous (in our case, about 10% of our nodes, or 40 nodes) of our nodes reporting SNMP outages:

      SNMP data collection on interface 192.168.x.x failed with 'Unexpected error during node SNMP collection for: 192.168.x.x'.

      Most, but not all (in our case, about 85%) receive the following:

      The SNMP outage on interface 192.168.x.x has been cleared. Service is restored

      In addition to the email noise regarding these false positives, about 15% of the nodes remain in the "Nodes with Pending Problems" list.

        Attachments

          Activity

            People

            • Assignee:
              j-white Jesse White
              Reporter:
              aaron.scamehorn@cogcap.com Aaron Scamehorn
            • Votes:
              3 Vote for this issue
              Watchers:
              10 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: