id
.1.3.6.1.4.1.231.7.2.9.6
generic
6
specific
1
uei.opennms.org/vendor/siemens/traps/hipath3000/sendAlarm
H150E-MIB defined trap event: sendAlarm
<p>If an error occurs, there will be checked if the errorClass is configured
to trigger an immediate signalling. If so, a trap will be send to the
management station containing the information shown above.</p><table>
<tr><td><b>
h150eErrorIndex</b></td><td>
%parm[#1]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eErrorDateTime</b></td><td>
%parm[#2]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eErrorClass</b></td><td>
%parm[#3]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eErrorCode</b></td><td>
%parm[#4]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eAccessSlot</b></td><td>
%parm[#5]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eAccessPort</b></td><td>
%parm[#6]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eErrorDescription</b></td><td>
%parm[#7]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eSysState</b></td><td>
%parm[#8]%;</td><td><p>
normal(1)
warning(2)
minor(3)
major(4)
critical(5)
</p></td></tr>
<tr><td><b>
h150eErrorSeverity</b></td><td>
%parm[#9]%;</td><td><p>
normal(1)
warning(2)
minor(3)
major(4)
critical(5)
</p></td></tr></table>
<p>
sendAlarm trap received
h150eErrorIndex=%parm[#1]%
h150eErrorDateTime=%parm[#2]%
h150eErrorClass=%parm[#3]%
h150eErrorCode=%parm[#4]%
h150eAccessSlot=%parm[#5]%
h150eAccessPort=%parm[#6]%
h150eErrorDescription=%parm[#7]%
h150eSysState=%parm[#8]%
h150eErrorSeverity=%parm[#9]%</p>
Indeterminate
parm[#8]
parm[#9]
id
.1.3.6.1.4.1.231.7.2.9.6
generic
6
specific
2
uei.opennms.org/vendor/siemens/traps/hipath3000/sendCdrNotification
H150E-MIB defined trap event: sendCdrNotification
<p>The CDR notification trap is sent to trigger further actions by the management
station, for instance download of CDR data.</p><table>
<tr><td><b>
h150eIndexOfLastCdrNotificationTrap</b></td><td>
%parm[#1]%;</td><td><p></p></td></tr>
<tr><td><b>
h150etypeOfLastCdrNotificationTrap</b></td><td>
%parm[#2]%;</td><td><p></p></td></tr>
<tr><td><b>
h150eDescriptionOfLastCdrNotificationTrap</b></td><td>
%parm[#3]%;</td><td><p></p></td></tr></table>
<p>
sendCdrNotification trap received
h150eIndexOfLastCdrNotificationTrap=%parm[#1]%
h150etypeOfLastCdrNotificationTrap=%parm[#2]%
h150eDescriptionOfLastCdrNotificationTrap=%parm[#3]%</p>
Indeterminate
id
.1.3.6.1.4.1.231.7.2.9.6
generic
6
specific
3
uei.opennms.org/vendor/siemens/traps/hipath3000/sendPortStatusNotification
H150E-MIB defined trap event: sendPortStatusNotification
<p>The 'port status change' notification trap is sent to trigger a polling of the
port table by a management station. It indicates one or more changes in port
states.</p><table>
<tr><td><b>
indexOfLastPortStatusNotificationTrap</b></td><td>
%parm[#1]%;</td><td><p></p></td></tr></table>
<p>
sendPortStatusNotification trap received
indexOfLastPortStatusNotificationTrap=%parm[#1]%</p>
Indeterminate
id
.1.3.6.1.4.1.231.7.2.9.6
generic
6
specific
4
uei.opennms.org/vendor/siemens/traps/hipath3000/sendUmRelatedChangeNotification
H150E-MIB defined trap event: sendUmRelatedChangeNotification
<p>This trap is sent (to UM proxy), as the system detects changes.</p><table>
<tr><td><b>
umTrapIdentifier</b></td><td>
%parm[#1]%;</td><td><p></p></td></tr>
<tr><td><b>
umTrapType</b></td><td>
%parm[#2]%;</td><td><p>
startup(0)
modifyGeneral(1)
modifySubscriber(2)
</p></td></tr>
<tr><td><b>
umTrapLogicalPortNumber</b></td><td>
%parm[#3]%;</td><td><p></p></td></tr>
<tr><td><b>
umNetworkElementKey</b></td><td>
%parm[#4]%;</td><td><p></p></td></tr></table>
<p>
sendUmRelatedChangeNotification trap received
umTrapIdentifier=%parm[#1]%
umTrapType=%parm[#2]%
umTrapLogicalPortNumber=%parm[#3]%
umNetworkElementKey=%parm[#4]%</p>
Indeterminate
parm[#2]