id
.1.3.6.1.2.1.11
generic
6
specific
0
uei.opennms.org/mib2opennms/coldStart
CONTIVITY-TRAPS-V1-MIB defined trap event: coldStart
<p>A coldStart trap signifies that the SNMPv2 entity, acting
in an agent role, is reinitializing itself and that its
configuration may have been altered.</p><table></table>
<p>
coldStart trap received</p>
Normal
id
.1.3.6.1.2.1.11
generic
6
specific
2
uei.opennms.org/mib2opennms/linkDown
CONTIVITY-TRAPS-V1-MIB defined trap event: linkDown
<p>A linkDown trap signifies that the sending
protocol entity recognizes a failure in one of
the communication links represented in the
agent's configuration.
Varbind list:
ifIndex -- ifIndex of the interface.
ifAdminStatus -- ifAdminStatus of the interface.
ifOperStatus -- ifOperStatus of the interface.
ifDescr -- ifDescr of the interface.
ifType -- ifType, this provides descrimination of interfaces that are tunnels.
ifReasonForStatus-ces -- reason for the change in status.
ifPhysLocation-ces -- this is the slot number.
ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation.
ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel.
ifName-ces -- Name of the tunnel or physical interface.
ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero.
sysObjectID -- sysObjectID of the unit.
sysName -- sysName of the unit.</p><table>
<tr><td><b>
ifIndex</b></td><td>
%parm[#1]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifAdminStatus</b></td><td>
%parm[#2]%;</td><td><p;>
up(1)
down(2)
testing(3)
</p></td;></tr>
<tr><td><b>
ifOperStatus</b></td><td>
%parm[#3]%;</td><td><p;>
up(1)
down(2)
testing(3)
</p></td;></tr>
<tr><td><b>
ifDescr</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifType</b></td><td>
%parm[#5]%;</td><td><p;>
other(1)
regular1822(2)
hdh1822(3)
ddn-x25(4)
rfc877-x25(5)
ethernet-csmacd(6)
iso88023-csmacd(7)
iso88024-tokenBus(8)
iso88025-tokenRing(9)
iso88026-man(10)
starLan(11)
proteon-10Mbit(12)
proteon-80Mbit(13)
hyperchannel(14)
fddi(15)
lapb(16)
sdlc(17)
ds1(18)
e1(19)
basicISDN(20)
primaryISDN(21)
propPointToPointSerial(22)
ppp(23)
softwareLoopback(24)
eon(25)
ethernet-3Mbit(26)
nsip(27)
slip(28)
ultra(29)
ds3(30)
sip(31)
frame-relay(32)
</p></td;></tr>
<tr><td><b>
ifReasonForStatus-ces</b></td><td>
%parm[#6]%;</td><td><p;>
unknown(1)
idle-time-out(2)
ip-addr-chg(3)
no-response(4)
user-interaction(5)
time-limit(6)
testing(7)
test-complete-success(8)
test-complete-failure(9)
link-down(10)
link-up(11)
</p></td;></tr>
<tr><td><b>
ifPhysLocation-ces</b></td><td>
%parm[#7]%;</td><td><p;>
motherBoardOrSlot0(1)
slot1(2)
slot2(3)
slot3(4)
slot4(5)
slot5(6)
</p></td;></tr>
<tr><td><b>
ifPhysRelPos-ces</b></td><td>
%parm[#8]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifIpAddr-ces</b></td><td>
%parm[#9]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifName-ces</b></td><td>
%parm[#10]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifTunnelRemoteIpAddr-ces</b></td><td>
%parm[#11]%;</td><td><p;></p></td;></tr>
<tr><td><b>
sysObjectID</b></td><td>
%parm[#12]%;</td><td><p;></p></td;></tr>
<tr><td><b>
sysName</b></td><td>
%parm[#13]%;</td><td><p;></p></td;></tr></table>
<p>
linkDown trap received
ifIndex=%parm[#1]%
ifAdminStatus=%parm[#2]%
ifOperStatus=%parm[#3]%
ifDescr=%parm[#4]%
ifType=%parm[#5]%
ifReasonForStatus-ces=%parm[#6]%
ifPhysLocation-ces=%parm[#7]%
ifPhysRelPos-ces=%parm[#8]%
ifIpAddr-ces=%parm[#9]%
ifName-ces=%parm[#10]%
ifTunnelRemoteIpAddr-ces=%parm[#11]%
sysObjectID=%parm[#12]%
sysName=%parm[#13]%</p>
Minor
id
.1.3.6.1.2.1.11
generic
6
specific
3
uei.opennms.org/mib2opennms/linkUp
CONTIVITY-TRAPS-V1-MIB defined trap event: linkUp
<p>A linkUp trap signifies that the sending
protocol entity recognizes that one of the
communication links represented in the agent's
configuration has come up.
Varbind list:
ifIndex -- ifIndex of the interface.
ifAdminStatus -- ifAdminStatus of the interface.
ifOperStatus -- ifOperStatus of the interface.
ifDescr -- ifDescr of the interface.
ifType -- ifType, this provides descrimination of interfaces that are tunnels.
ifReasonForStatus-ces -- reason for the change in status
ifPhysLocation-ces -- this is the slot number.
ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation.
ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel.
ifName-ces -- Name of the tunnel or physical interface.
ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero.
sysObjectID -- sysObjectID of the unit.
sysName -- sysName of the unit.</p><table>
<tr><td><b>
ifIndex</b></td><td>
%parm[#1]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifAdminStatus</b></td><td>
%parm[#2]%;</td><td><p;>
up(1)
down(2)
testing(3)
</p></td;></tr>
<tr><td><b>
ifOperStatus</b></td><td>
%parm[#3]%;</td><td><p;>
up(1)
down(2)
testing(3)
</p></td;></tr>
<tr><td><b>
ifDescr</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifType</b></td><td>
%parm[#5]%;</td><td><p;>
other(1)
regular1822(2)
hdh1822(3)
ddn-x25(4)
rfc877-x25(5)
ethernet-csmacd(6)
iso88023-csmacd(7)
iso88024-tokenBus(8)
iso88025-tokenRing(9)
iso88026-man(10)
starLan(11)
proteon-10Mbit(12)
proteon-80Mbit(13)
hyperchannel(14)
fddi(15)
lapb(16)
sdlc(17)
ds1(18)
e1(19)
basicISDN(20)
primaryISDN(21)
propPointToPointSerial(22)
ppp(23)
softwareLoopback(24)
eon(25)
ethernet-3Mbit(26)
nsip(27)
slip(28)
ultra(29)
ds3(30)
sip(31)
frame-relay(32)
</p></td;></tr>
<tr><td><b>
ifReasonForStatus-ces</b></td><td>
%parm[#6]%;</td><td><p;>
unknown(1)
idle-time-out(2)
ip-addr-chg(3)
no-response(4)
user-interaction(5)
time-limit(6)
testing(7)
test-complete-success(8)
test-complete-failure(9)
link-down(10)
link-up(11)
</p></td;></tr>
<tr><td><b>
ifPhysLocation-ces</b></td><td>
%parm[#7]%;</td><td><p;>
motherBoardOrSlot0(1)
slot1(2)
slot2(3)
slot3(4)
slot4(5)
slot5(6)
</p></td;></tr>
<tr><td><b>
ifPhysRelPos-ces</b></td><td>
%parm[#8]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifIpAddr-ces</b></td><td>
%parm[#9]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifName-ces</b></td><td>
%parm[#10]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifTunnelRemoteIpAddr-ces</b></td><td>
%parm[#11]%;</td><td><p;></p></td;></tr>
<tr><td><b>
sysObjectID</b></td><td>
%parm[#12]%;</td><td><p;></p></td;></tr>
<tr><td><b>
sysName</b></td><td>
%parm[#13]%;</td><td><p;></p></td;></tr></table>
<p>
linkUp trap received
ifIndex=%parm[#1]%
ifAdminStatus=%parm[#2]%
ifOperStatus=%parm[#3]%
ifDescr=%parm[#4]%
ifType=%parm[#5]%
ifReasonForStatus-ces=%parm[#6]%
ifPhysLocation-ces=%parm[#7]%
ifPhysRelPos-ces=%parm[#8]%
ifIpAddr-ces=%parm[#9]%
ifName-ces=%parm[#10]%
ifTunnelRemoteIpAddr-ces=%parm[#11]%
sysObjectID=%parm[#12]%
sysName=%parm[#13]%</p>
Normal
id
.1.3.6.1.2.1.11
generic
6
specific
5
uei.opennms.org/mib2opennms/authenticationFailure
CONTIVITY-TRAPS-V1-MIB defined trap event: authenticationFailure
<p>An authenticationFailure trap signifies that the SNMPv2
entity, acting in an agent role, has received a protocol
message that is not properly authenticated.
The snmpEnableAuthenTraps object indicates
whether this trap will be generated.
snmpAuthenOperation-ces identifies the operation( ie. GetRequest,
GetNextRequest,... ) was being attempted.
snmpAuthenIpAddress-ces identifies the source IP address of
the operation.
snmpAuthenCommString-ces identifies the community string that
was used in the operation.</p><table>
<tr><td><b>
snmpAuthenOperation-ces</b></td><td>
%parm[#1]%;</td><td><p;>
getRequest(160)
getNextRequest(161)
setRequest(163)
getBulkRequest(165)
</p></td;></tr>
<tr><td><b>
snmpAuthenIpAddress-ces</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
snmpAuthenCommString-ces</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
sysObjectID</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
sysName</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr></table>
<p>
authenticationFailure trap received
snmpAuthenOperation-ces=%parm[#1]%
snmpAuthenIpAddress-ces=%parm[#2]%
snmpAuthenCommString-ces=%parm[#3]%
sysObjectID=%parm[#4]%
sysName=%parm[#5]%</p>
Warning
id
.1.3.6.1.4.1.2505.1
generic
6
specific
401
uei.opennms.org/mib2opennms/powerUpTrapEntry
CONTIVITY-TRAPS-V1-MIB defined trap event: powerUpTrapEntry
<p>Power Up</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
powerUpTrap</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
powerUpTrapEntry trap received
severityLevel=%parm[#1]%
powerUpTrap=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1
generic
6
specific
601
uei.opennms.org/mib2opennms/periodicHeartbeatTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: periodicHeartbeatTrap
<p>Periodic Heartbeat</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
periodicHeartbeat</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
periodicHeartbeatTrap trap received
severityLevel=%parm[#1]%
periodicHeartbeat=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1001
uei.opennms.org/mib2opennms/hardDisk1StatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: hardDisk1StatusTrap
<p>Hard Disk Number 1 Status</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
hardDisk1Status</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
hardDisk1StatusTrap trap received
severityLevel=%parm[#1]%
hardDisk1Status=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1002
uei.opennms.org/mib2opennms/hardDisk0StatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: hardDisk0StatusTrap
<p>Hard Disk Number 0 Status</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
hardDisk0Status</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
hardDisk0StatusTrap trap received
severityLevel=%parm[#1]%
hardDisk0Status=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1003
uei.opennms.org/mib2opennms/memoryUsageTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: memoryUsageTrap
<p>Memory Usage Status</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
memoryUsage</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
memoryUsageTrap trap received
severityLevel=%parm[#1]%
memoryUsage=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1004
uei.opennms.org/mib2opennms/lanCardStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: lanCardStatusTrap
<p>Status of any LAN cards on the system</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
lanCardStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifIndex</b></td><td>
%parm[#7]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifDescr</b></td><td>
%parm[#8]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifType</b></td><td>
%parm[#9]%;</td><td><p;>
other(1)
regular1822(2)
hdh1822(3)
ddn-x25(4)
rfc877-x25(5)
ethernet-csmacd(6)
iso88023-csmacd(7)
iso88024-tokenBus(8)
iso88025-tokenRing(9)
iso88026-man(10)
starLan(11)
proteon-10Mbit(12)
proteon-80Mbit(13)
hyperchannel(14)
fddi(15)
lapb(16)
sdlc(17)
ds1(18)
e1(19)
basicISDN(20)
primaryISDN(21)
propPointToPointSerial(22)
ppp(23)
softwareLoopback(24)
eon(25)
ethernet-3Mbit(26)
nsip(27)
slip(28)
ultra(29)
ds3(30)
sip(31)
frame-relay(32)
</p></td;></tr></table>
<p>
lanCardStatusTrap trap received
severityLevel=%parm[#1]%
lanCardStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%
ifIndex=%parm[#7]%
ifDescr=%parm[#8]%
ifType=%parm[#9]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1005
uei.opennms.org/mib2opennms/cpuTwoStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: cpuTwoStatusTrap
<p>Status of second CPU.</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
cpuTwoStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
cpuTwoStatusTrap trap received
severityLevel=%parm[#1]%
cpuTwoStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1006
uei.opennms.org/mib2opennms/fanOneStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: fanOneStatusTrap
<p>Status of the first CPU fan</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
fanOneStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
fanOneStatusTrap trap received
severityLevel=%parm[#1]%
fanOneStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1007
uei.opennms.org/mib2opennms/fanTwoStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: fanTwoStatusTrap
<p>Status of the second CPU fan</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
fanTwoStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
fanTwoStatusTrap trap received
severityLevel=%parm[#1]%
fanTwoStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1008
uei.opennms.org/mib2opennms/chassisFanStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: chassisFanStatusTrap
<p>Status of the chassis fan.</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
chassisFanStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
chassisFanStatusTrap trap received
severityLevel=%parm[#1]%
chassisFanStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
1009
uei.opennms.org/mib2opennms/fiveVoltsPosStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: fiveVoltsPosStatusTrap
<p>Status of the +5 Volt power</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
fiveVoltsPositive</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
fiveVoltsPosStatusTrap trap received
severityLevel=%parm[#1]%
fiveVoltsPositive=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10010
uei.opennms.org/mib2opennms/fiveVoltsMinusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: fiveVoltsMinusTrap
<p>Status of -5 Volt power</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
fiveVoltsMinus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
fiveVoltsMinusTrap trap received
severityLevel=%parm[#1]%
fiveVoltsMinus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10011
uei.opennms.org/mib2opennms/threeVoltsPositiveTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: threeVoltsPositiveTrap
<p>Status of +3 Volt power</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
threeVoltsPositive</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
threeVoltsPositiveTrap trap received
severityLevel=%parm[#1]%
threeVoltsPositive=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10012
uei.opennms.org/mib2opennms/twoDotFiveVATrap
CONTIVITY-TRAPS-V1-MIB defined trap event: twoDotFiveVATrap
<p>Status of 2.5VA power</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
twoDotFiveVA</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
twoDotFiveVATrap trap received
severityLevel=%parm[#1]%
twoDotFiveVA=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10013
uei.opennms.org/mib2opennms/twoDotFiveVBTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: twoDotFiveVBTrap
<p>Status of 2.5VB power</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
twoDotFiveVB</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
twoDotFiveVBTrap trap received
severityLevel=%parm[#1]%
twoDotFiveVB=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10014
uei.opennms.org/mib2opennms/twelveVoltsPositveTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: twelveVoltsPositveTrap
<p>Status of +12 Volt power</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
twelveVoltsPositive</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
twelveVoltsPositveTrap trap received
severityLevel=%parm[#1]%
twelveVoltsPositive=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10015
uei.opennms.org/mib2opennms/twelveVoltsMinsTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: twelveVoltsMinsTrap
<p>Status of -12 Volt power</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
twelveVoltsMinus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
twelveVoltsMinsTrap trap received
severityLevel=%parm[#1]%
twelveVoltsMinus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10016
uei.opennms.org/mib2opennms/normalTemperatureTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: normalTemperatureTrap
<p>Status of the normal temperature reading</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
normalTemperature</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
normalTemperatureTrap trap received
severityLevel=%parm[#1]%
normalTemperature=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Normal
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10017
uei.opennms.org/mib2opennms/criticalTemperatureTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: criticalTemperatureTrap
<p>Status of the critical temperature reading</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
criticalTemperature</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
criticalTemperatureTrap trap received
severityLevel=%parm[#1]%
criticalTemperature=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Critical
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10018
uei.opennms.org/mib2opennms/chassisIntrusionTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: chassisIntrusionTrap
<p>The chassis intrusion sensor indicates that the unit has been physically opened</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
chassisIntrusion</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
chassisIntrusionTrap trap received
severityLevel=%parm[#1]%
chassisIntrusion=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Warning
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10019
uei.opennms.org/mib2opennms/dualPowerSupplyTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: dualPowerSupplyTrap
<p>Status of the redundant power supplies</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
dualPowerSupply</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
dualPowerSupplyTrap trap received
severityLevel=%parm[#1]%
dualPowerSupply=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10020
uei.opennms.org/mib2opennms/t1WANStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: t1WANStatusTrap
<p>Status of T1 WAN card(s).
Possible Values:
For Wanic support:
Alert: Invalid Device X
Warning: Device WanicX disabled
Alert: Device WanicX down
Warning: Device WanicX not initialized
Warning: Device WanicX PPP negotiating
Alert: Device WanicX PPP down
Alert: Device WanicX FR no support
Alert: Device WanicX Unknown DL
For T1:
Alert: Invalid Device X
Warning: Device LMCDTEX disabled
Alert: Device LMCDTEX down
Warning: Device LMCDTEX not initialized
For CSU/DSU:
Alert: Invalid Device X
Warning: Device LMCCDX disabled
Alert: Device LMCCDX down
Warning: Device LMCCDX not initialized</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
t1WANStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifIndex</b></td><td>
%parm[#7]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifDescr</b></td><td>
%parm[#8]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifType</b></td><td>
%parm[#9]%;</td><td><p;>
other(1)
regular1822(2)
hdh1822(3)
ddn-x25(4)
rfc877-x25(5)
ethernet-csmacd(6)
iso88023-csmacd(7)
iso88024-tokenBus(8)
iso88025-tokenRing(9)
iso88026-man(10)
starLan(11)
proteon-10Mbit(12)
proteon-80Mbit(13)
hyperchannel(14)
fddi(15)
lapb(16)
sdlc(17)
ds1(18)
e1(19)
basicISDN(20)
primaryISDN(21)
propPointToPointSerial(22)
ppp(23)
softwareLoopback(24)
eon(25)
ethernet-3Mbit(26)
nsip(27)
slip(28)
ultra(29)
ds3(30)
sip(31)
frame-relay(32)
</p></td;></tr></table>
<p>
t1WANStatusTrap trap received
severityLevel=%parm[#1]%
t1WANStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%
ifIndex=%parm[#7]%
ifDescr=%parm[#8]%
ifType=%parm[#9]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10021
uei.opennms.org/mib2opennms/t3WANStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: t3WANStatusTrap
<p>Status of T3 WAN card
Possible Values:
Alert: Invalid Index X
Warning: Device HSSIX disabled
Alert: Device HSSIX down
Warning: Device HSSIX not initialized
Alert: Device HSSIX PPP down
Warning: Device HSSIX PP initializing</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
t3WANStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifIndex</b></td><td>
%parm[#7]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifDescr</b></td><td>
%parm[#8]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifType</b></td><td>
%parm[#9]%;</td><td><p;>
other(1)
regular1822(2)
hdh1822(3)
ddn-x25(4)
rfc877-x25(5)
ethernet-csmacd(6)
iso88023-csmacd(7)
iso88024-tokenBus(8)
iso88025-tokenRing(9)
iso88026-man(10)
starLan(11)
proteon-10Mbit(12)
proteon-80Mbit(13)
hyperchannel(14)
fddi(15)
lapb(16)
sdlc(17)
ds1(18)
e1(19)
basicISDN(20)
primaryISDN(21)
propPointToPointSerial(22)
ppp(23)
softwareLoopback(24)
eon(25)
ethernet-3Mbit(26)
nsip(27)
slip(28)
ultra(29)
ds3(30)
sip(31)
frame-relay(32)
</p></td;></tr></table>
<p>
t3WANStatusTrap trap received
severityLevel=%parm[#1]%
t3WANStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%
ifIndex=%parm[#7]%
ifDescr=%parm[#8]%
ifType=%parm[#9]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10022
uei.opennms.org/mib2opennms/hwAccelTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: hwAccelTrap
<p>Status of hardware accelerator card.
Possible Values:
Invalid hardware accelerator unit %d;
Unknown hardware accelerator unit %d;
Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED;
Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED;
Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE;
Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING;
Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN;
Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED;
</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
hwAccelStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
hwAccelTrap trap received
severityLevel=%parm[#1]%
hwAccelStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10024
uei.opennms.org/mib2opennms/v90WANStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: v90WANStatusTrap
<p>Status of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: V.90 Invalid index X
Disabled: Device IntModem-X disabled
Healthy: Device IntModem-X: PPP is UP.
Alert: Device IntModem-X down
Warning: Device IntModem-X not initialized
Alert: Device IntModem-X: Call is UP. Internal Error.
Warning: Device IntModem-X is Down. Last dial-out attempt FAILED.
Healthy: Device IntModem-X is Down (No Active calls)
Warning: Device IntModem-X is in an UNKNOWN state</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
v90WANStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
v90WANStatusTrap trap received
severityLevel=%parm[#1]%
v90WANStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10025
uei.opennms.org/mib2opennms/briWANStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: briWANStatusTrap
<p>Status of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: BRI Invalid index X
Alert: Device BRI-X not Responding. Needs Host Reboot.
Disabled: Device BRI-X disabled
Alert: Device BRI-X down
Warning: Device BRI-X not initialized
Healthy: Device BRI-X: PPP is UP.
Alert: Device BRI-X: Call is UP. Internal Error.
Warning: Device BRI-X is Down. Last dial-out attempt FAILED.
Healthy: Device BRI-X is Down (No Active calls)
Alert: Device BRI-X is in an UNKNOWN state</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
briWANStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
briWANStatusTrap trap received
severityLevel=%parm[#1]%
briWANStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10026
uei.opennms.org/mib2opennms/serUartStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: serUartStatusTrap
<p>Status of Serial (COM) port/interface
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: COM port Invalid index X
Healthy: Device COMX is set for Serial Menu.
Disabled: Device COMX disabled
Warning: Device COMX not initialized
Healthy: Device COMX: PPP is UP.
Alert: Device COMX: Call is UP. Internal Error.
Warning: Device COMX is Down. Last dial-out attempt FAILED.
Healthy: Device COMX is Down (No Active calls)
Alert: Device COMX is in an UNKNOWN state</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
serUartStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
serUartStatusTrap trap received
severityLevel=%parm[#1]%
serUartStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.1
generic
6
specific
10027
uei.opennms.org/mib2opennms/adslWANStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: adslWANStatusTrap
<p>Status of ADI ADSL card
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: Invalid index X
Alert: Device ADIADSLX off line
Disabled: Device ADIADSLX disabled
Alert: Device ADIADSLX down
Warning: Device ADIADSLX not initialized
Healthy: Device ADIADSLX up</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
adslWANStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
adslWANStatusTrap trap received
severityLevel=%parm[#1]%
adslWANStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3001
uei.opennms.org/mib2opennms/radiusAcctServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: radiusAcctServerTrap
<p>Status of External Radius Accounting Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
radiusAcctServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
radiusAcctServerTrap trap received
severityLevel=%parm[#1]%
radiusAcctServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3002
uei.opennms.org/mib2opennms/backupServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: backupServerTrap
<p>Status of External Disk Backup Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
backupServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
backupServerTrap trap received
severityLevel=%parm[#1]%
backupServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3003
uei.opennms.org/mib2opennms/diskRedundencyTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: diskRedundencyTrap
<p>Status of Local Disk Redundency</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
diskRedundency</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
diskRedundencyTrap trap received
severityLevel=%parm[#1]%
diskRedundency=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3004
uei.opennms.org/mib2opennms/intLDAPServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: intLDAPServerTrap
<p>Status of Internal LDAP Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
intLDAPServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
intLDAPServerTrap trap received
severityLevel=%parm[#1]%
intLDAPServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3005
uei.opennms.org/mib2opennms/loadBalancingServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: loadBalancingServerTrap
<p>Status of Load Balancing Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
loadBalancingServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
loadBalancingServerTrap trap received
severityLevel=%parm[#1]%
loadBalancingServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3006
uei.opennms.org/mib2opennms/dnsServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: dnsServerTrap
<p>Status of DNS Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
dnsServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
dnsServerTrap trap received
severityLevel=%parm[#1]%
dnsServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3007
uei.opennms.org/mib2opennms/snmpServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: snmpServerTrap
<p>Status of SNMP Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
snmpServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
snmpServerTrap trap received
severityLevel=%parm[#1]%
snmpServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Normal
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3008
uei.opennms.org/mib2opennms/ipAddressPoolTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: ipAddressPoolTrap
<p>Status of the IP address pool</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
ipAddressPool</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
ipAddressPoolTrap trap received
severityLevel=%parm[#1]%
ipAddressPool=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
3009
uei.opennms.org/mib2opennms/extLDAPServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: extLDAPServerTrap
<p>Status of External LDAP Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
extLDAPServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
extLDAPServerTrap trap received
severityLevel=%parm[#1]%
extLDAPServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
30010
uei.opennms.org/mib2opennms/radiusAuthServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: radiusAuthServerTrap
<p>Status of Radius Authentication Server</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
radiusAuthServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
radiusAuthServerTrap trap received
severityLevel=%parm[#1]%
radiusAuthServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
30011
uei.opennms.org/mib2opennms/certificateServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: certificateServerTrap
<p>Status of Certificates Validity
Possible Values:
Healthy: Certificates Validity: Operational;
Alert: Certificates Validity: All certificates are going to expire/expired;
Warning: Certificates Validity: One/more certificate is invalid;
Disabled: Certificates Validity: No certificate defined;
</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
certificateServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
certificateServerTrap trap received
severityLevel=%parm[#1]%
certificateServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
30012
uei.opennms.org/mib2opennms/extLDAPAuthServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: extLDAPAuthServerTrap
<p>Status of External LDAP Authentication Server.
Possible Values:
Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable);
Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
certificateServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
extLDAPAuthServerTrap trap received
severityLevel=%parm[#1]%
certificateServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
30013
uei.opennms.org/mib2opennms/cmpServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: cmpServerTrap
<p>Status of CMP Server.
Possible Values:
One/more Certificate Requests error: there is at least one request error;
One/more Certificate Requests processing: there is at least one request in processing;
No Certificate Requests submitted: there is no request sent;</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
cmpServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
cmpServerTrap trap received
severityLevel=%parm[#1]%
cmpServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.2
generic
6
specific
30014
uei.opennms.org/mib2opennms/dhcpServerTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: dhcpServerTrap
<p>Status of DHCP Server
Possible Values:
Disabled: DHCP Server is Disabled
Alert: DHCP Server is NOT configured
Alert: DHCP Server is configured and operational, Using backup config
Alert: No IP Address available for subnet
Alert: DHCP Server is configured and server is DOWN
Healthy: DHCP Server is Operational
Warning: Subnet low on IP Addresses
Warning: DHCP Server Initializing
Warning: DHCP Server is Enabled, but status Unknown cannot be determined</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
dhcpServer</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
dhcpServerTrap trap received
severityLevel=%parm[#1]%
dhcpServer=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.3
generic
6
specific
5001
uei.opennms.org/mib2opennms/netBuffersTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: netBuffersTrap
<p>Network buffer usage</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
netBuffers</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
netBuffersTrap trap received
severityLevel=%parm[#1]%
netBuffers=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.3
generic
6
specific
5002
uei.opennms.org/mib2opennms/fireWallTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: fireWallTrap
<p>Status of internal firewall</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
fireWall</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
fireWallTrap trap received
severityLevel=%parm[#1]%
fireWall=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.3
generic
6
specific
5003
uei.opennms.org/mib2opennms/fipsStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: fipsStatusTrap
<p>Status of FIPS</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
fipsStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
fipsStatusTrap trap received
severityLevel=%parm[#1]%
fipsStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.3
generic
6
specific
5004
uei.opennms.org/mib2opennms/licensingStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: licensingStatusTrap
<p>Status temporary SW Licenses</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
licensingStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
licensingStatusTrap trap received
severityLevel=%parm[#1]%
licensingStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.3
generic
6
specific
5005
uei.opennms.org/mib2opennms/natStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: natStatusTrap
<p>Status of Network Address Translator</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
natStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
natStatusTrap trap received
severityLevel=%parm[#1]%
natStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.3
generic
6
specific
5006
uei.opennms.org/mib2opennms/antiSpoofingStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: antiSpoofingStatusTrap
<p>Status of Anti Spoofing Feature</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
antiSpoofingStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
antiSpoofingStatusTrap trap received
severityLevel=%parm[#1]%
antiSpoofingStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Warning
id
.1.3.6.1.4.1.2505.1.3
generic
6
specific
5007
uei.opennms.org/mib2opennms/sslVpnStatusTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: sslVpnStatusTrap
<p>Status of SSL-VPN Accelerator</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
sslVpnStatus</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
sslVpnStatusTrap trap received
severityLevel=%parm[#1]%
sslVpnStatus=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Indeterminate
id
.1.3.6.1.4.1.2505.1.4
generic
6
specific
101
uei.opennms.org/mib2opennms/failedLoginTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: failedLoginTrap
<p>Failed Login Attempt</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
failedLogin</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
failedLoginTrap trap received
severityLevel=%parm[#1]%
failedLogin=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Warning
id
.1.3.6.1.4.1.2505.1.5
generic
6
specific
201
uei.opennms.org/mib2opennms/securityIntrusionTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: securityIntrusionTrap
<p>Security Intrusion</p><table>
<tr><td><b>
severityLevel</b></td><td>
%parm[#1]%;</td><td><p;>
alert(1)
warning(2)
disabled(3)
healthy(4)
unknown(5)
</p></td;></tr>
<tr><td><b>
securityIntrusion</b></td><td>
%parm[#2]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemName</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemDate</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemTime</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
systemUpTime</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr></table>
<p>
securityIntrusionTrap trap received
severityLevel=%parm[#1]%
securityIntrusion=%parm[#2]%
systemName=%parm[#3]%
systemDate=%parm[#4]%
systemTime=%parm[#5]%
systemUpTime=%parm[#6]%</p>
Minor
id
.1.3.6.1.4.1.2505.1.14.3
generic
6
specific
1
uei.opennms.org/mib2opennms/firewallRuleTriggeredTrap
CONTIVITY-TRAPS-V1-MIB defined trap event: firewallRuleTriggeredTrap
<p>An event sent at the user's request to signal that a rule has
been matched.
firewallPolicyType-ces -- Policy type.
firewallRuleType-ces -- Type of rule that triggered this event.
firewallRuleNumber-ces -- Number of the rule that triggered this event.
ifIndex -- ifIndex is the index into the ifTable for port that received the packet.
ifName-ces -- The name of the interface, same as ifName.
firewallSrcAddr-ces -- Source IP address of the packet.
firewallSrcPort-ces -- Source port address of the packet.
firewallDestAddr-ces -- Destination IP address of the packet.
firewallDestPort-ces -- Destination port of the packet.
firewallProtocolID-ces -- The value of the protocol field in the IP header.
firewallRuleAction-ces -- Action defined for the triggered rule.</p><table>
<tr><td><b>
firewallPolicyType-ces</b></td><td>
%parm[#1]%;</td><td><p;>
firewall(1)
nat(2)
</p></td;></tr>
<tr><td><b>
firewallRuleType-ces</b></td><td>
%parm[#2]%;</td><td><p;>
over-ride(1)
sourceInterface(2)
destinationInterface(3)
default(4)
</p></td;></tr>
<tr><td><b>
firewallRuleNumber-ces</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifIndex</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
ifName-ces</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
firewallSrcAddr-ces</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr>
<tr><td><b>
firewallSrcPort-ces</b></td><td>
%parm[#7]%;</td><td><p;></p></td;></tr>
<tr><td><b>
firewallDestAddr-ces</b></td><td>
%parm[#8]%;</td><td><p;></p></td;></tr>
<tr><td><b>
firewallDestPort-ces</b></td><td>
%parm[#9]%;</td><td><p;></p></td;></tr>
<tr><td><b>
firewallProtocolID-ces</b></td><td>
%parm[#10]%;</td><td><p;></p></td;></tr>
<tr><td><b>
firewallRuleAction-ces</b></td><td>
%parm[#11]%;</td><td><p;>
unknown(1)
allow(2)
reject(3)
drop(4)
</p></td;></tr>
<tr><td><b>
sysObjectID</b></td><td>
%parm[#12]%;</td><td><p;></p></td;></tr>
<tr><td><b>
sysName</b></td><td>
%parm[#13]%;</td><td><p;></p></td;></tr></table>
<p>
firewallRuleTriggeredTrap trap received
firewallPolicyType-ces=%parm[#1]%
firewallRuleType-ces=%parm[#2]%
firewallRuleNumber-ces=%parm[#3]%
ifIndex=%parm[#4]%
ifName-ces=%parm[#5]%
firewallSrcAddr-ces=%parm[#6]%
firewallSrcPort-ces=%parm[#7]%
firewallDestAddr-ces=%parm[#8]%
firewallDestPort-ces=%parm[#9]%
firewallProtocolID-ces=%parm[#10]%
firewallRuleAction-ces=%parm[#11]%
sysObjectID=%parm[#12]%
sysName=%parm[#13]%</p>
Indeterminate