Cisco temperature threshold too low

Description

Hello,

This is opennms threshold default configuration for cisco:

<threshold type="high"
ds-type="ciscoEnvMonTemperatureStatusIndex" value="40.0"
rearm="37.0" trigger="3" ds-label="cvmTempStatusDescr" ds-name="cvmTempStatusValue"/>

40C is too low and OpenNMS keeps warning it. I'll change on my config but opennms should have default configs meeting Cisco limits. Yellow limit is 55 and red limit is 65. This is my output in Cisco C3750

#show env all
FAN is OK
TEMPERATURE is OK
Temperature Value: 39 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 55 Degree Celsius
Red Threshold : 65 Degree Celsius

Thanks!

Environment

Operating System: Linux Platform: PC

Acceptance / Success Criteria

None

Lucidchart Diagrams

Activity

Seth Leger December 6, 2011 at 4:44 PM

Fixed, I changed the threshold to 55C and the re-arm value to 50C.

commit 4a0e048ee53c68c2dc79834af229d478aae1e5be

Fixed

Details

Assignee

Reporter

Components

Fix versions

Affects versions

Priority

PagerDuty

Created January 29, 2010 at 2:02 PM
Updated January 27, 2017 at 4:26 PM
Resolved December 6, 2011 at 4:44 PM

Flag notifications